Alarms in OTN system and explanations

Optical Transport Network (OTN) systems have several alarms to monitor network health and detect issues that could impact performance. These alarms are categorized based on layers (OTU, ODU, and client signals) and types of failures. Here are the key OTN alarms and their explanations:

1. Optical Channel (OTU) Alarms

These alarms occur at the Optical Transport Unit (OTU) layer, which ensures error correction and transport.

  • LOF (Loss of Frame): The OTU cannot detect a valid frame alignment. This happens due to signal corruption.
  • LOS (Loss of Signal): No optical signal is detected, often due to fiber cuts or transceiver issues.
  • LOM (Loss of Multiframe): The multiframe alignment is lost, affecting higher-layer multiplexing.
  • OTUk-BDI (Backward Defect Indication): The remote end reports a defect at the OTUk layer, signaling back to the sender.
  • OTUk-SF (Signal Fail): Severe degradation in the signal, triggering protection switching.
  • OTUk-SD (Signal Degrade): The signal is degrading but hasn't yet failed completely.

2. Digital Section (ODU) Alarms

These alarms are at the Optical Data Unit (ODU) layer, which provides transport and multiplexing.

  • ODUk-AIS (Alarm Indication Signal): Upstream issues cause an all-ones pattern to be transmitted, indicating signal loss.
  • ODUk-OCI (Open Connection Indication): Indicates that a connection is unintentionally left open, possibly due to misconfiguration.
  • ODUk-LCK (Locked Defect): The ODU signal is locked, meaning the client signal is not mapped correctly.
  • ODUk-BDI (Backward Defect Indication): A remote node detects an issue and sends a backward notification.

3. Client Signal Alarms (Ethernet, SONET/SDH, etc.)

These alarms indicate problems with client signals being carried over OTN.

  • LOP (Loss of Pointer): The payload is misaligned within the ODU frame.
  • AIS (Alarm Indication Signal) at client level: The client signal is disrupted, sending an all-ones pattern.
  • BER Exceeded: Bit Error Rate exceeds the allowed threshold, indicating signal quality issues.

4. Optical Layer Alarms

These alarms monitor the physical layer of fiber optics.

  • High BER (Bit Error Rate): Too many bit errors detected, indicating fiber degradation.
  • Power Degradation: Optical power levels drop, possibly due to dirty connectors or fiber aging.
  • Chromatic Dispersion and PMD (Polarization Mode Dispersion): Signal distortion over long distances.

5. Equipment and Network Alarms

These alarms indicate hardware or network issues.

  • Card Failure: A hardware component has failed.
  • Link Down: A link between two nodes is inactive.
  • Protection Switch Triggered: The system switched to a backup path due to a failure.